Typically you can take that out to the nearest side wall like a gable wall and bring it right through the wall.
Bathroom vent terminates in attic.
Bathroom exhaust fans perform an important function by removing excess moisture from your home.
Options for venting a bathroom exhaust fan include best to worst.
When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form.
It seems like such an easy solution just leave a bathroom vent hose in an attic.
The very essence of a vent is to prevent siphon and vacuum forces in building up in the system it is also to provide an exit for the gases produced in the system.
A lot of options.
Bathroom vents terminates to attic.
Bathroom exhaust fan termination fittings locations clearance distances.
This point where the vent terminates and discharges the bathroom air should be checked for damage and to see that the air is actually exhausting properly.
No you should not vent a bathroom fan directly into an attic however you can vent a bathroom fan through an attic while it terminates on the roof or gable end.
All municipalities have different requirements but some do not draw a hard line on requiring exhaust fans.
The best exhaust fan venting is through smooth rigid ducts with taped joints and screwed to a special vent hood.
Bathroom code does address the issue of moving odor and moisture laden air from the bathroom to the outside.
That will take it from the bath exhaust fan to a discharge point.
Can i vent a bathroom fan into my attic.
That it is not blocked or restricted.
The inspector recommended that it terminates to the outside.
Now where the discharge point is is going to be up to you.
This article describes the proper closure or termination of bathroom exhaust fans fan ducts to prevent drafts heat loss leaks or even bird or rodent pest entry to the building.
Vent your bath and kitchen exhaust fans through the roof through a special roof hood.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
We also review recommended clearance distances between the bath exhaust duct end opening and other building features such as a gas fired.
And you would use a termination point a discharge point.
Bathroom ventilation fan duct routing routing a bath vent duct down out or up through an attic or roof out.
This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
The two most common locations for a bathroom vent to terminate is on top of the roof or through an exterior side wall.
Surprisingly bathroom fans are not required by some building codes.
Should i just place the bathroom vent next to the roof vent opening.