No you cannot vent your bathroom exhaust fan into the attic.
Bathroom vent duct in attic.
The ducting of your exhaust fan should be properly insulated.
If any lint or dust gets pushed out by your exhaust fan it risks accumulating on the inside of the vent pipe possibly blocking slowing both the drainage and ventilation.
This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
To determine which size fan to buy for your bath multiply the room s square footage by 1 1.
Insulating around a bathroom exhaust fan.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
The best exhaust fan venting is through smooth rigid ducts with taped joints and screwed to a special vent hood.
This system is quiet too.
Most exhaust fans are designed to use a 4 duct and instead it s going through a 1 5 diameter pipe.
Bathroom ventilation fan duct routing routing a bath vent duct down out or up through an attic or roof out.
Letting the fan exhaust into an open attic will cause moisture buildup on the underside of the roof.
Avoid venting through a soffit vent or ridge vent.
Here we provide specifications for recommended minimum maximum duct lengths for bathroom vent fans.
If so it indicates there is a leak in the vent cap.
A grille in each bathroom attaches to ducts which then fasten to a y connector at the fan.
Options for venting a bathroom exhaust fan include best to worst.
Bathroom exhaust fans perform an important function by removing excess moisture from your home.
The warm air will exhaust out the duct and enter back into the attic through the soffit vent or ridge vent.
When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form.
The bathroom exhaust ventilation fan disperses air through an opening in the fan housing which is usually 3 inches in diameter and ideally faces in the direction of the ventilation system outlet.
Otherwise the warm moist air will condense inside the duct.
You mount a switch in each bathroom.
The bathroom here is below an accessible attic so tom ran the exhaust duct across the attic and out a gable end.
Bathroom vent fans are rated by how many cubic feet of air they can move in one minute known as the cfm rating.
So that s where your attention should be.
Bathroom exhaust fan duct length specifications.
Venting through a roof vent or exhausting them in the attic could cause moisture problems and rot.
If you have access to the attic the fan can vent either through a gable wall or roof.
A bath vent fan duct that is too long may restrict air flow such that the fan is not functional.
A 3 or 4 inch duct connects to the outlet on the fan housing and runs to a side wall or to the roof and connects to a vent cap that allows the.
A bath vent fan duct that is too short may violate the manufacturer s installation instructions may not work properly or may be drafty.
However you will be suffering more likely because of the poor insulation.
Because the fan is in the attic you ll hardly hear it.