You have no issue with frost heave in this situation.
Basement support post footing.
Supporting column foundations for houses should be 2 feet widex 2 feet long x 2 feet deep and be on solid undisturb ground.
Scrape loose soil from the bottom of the hole until you reach the undisturbed soil.
Excavate the footing hole to the specified size digging the sides and bottom of the hole square and level.
When you pour the slab around the base of the column you help secure it in place.
If that s the case the top of the footer just needs to be below the bottom of the basement slab.
At its highest setting.
In weaker soils the author recommends casting an augmented footing alongside the existing footing above connected by dowels epoxied into the side of the existing footing.
With the post removed break out an undersized footing with a sledgehammer and shovel wear goggles and gloves and pour the new one.
For pricing and availability.
A typical size footing would be two foot square and one foot thick.
Akron big moe 56 in adjustable jack post.
It should project on both sides no less than 2 inches.
They are made from metal and have an adjustable screw top that can be raised to fit the space between the floor and ceiling of the basement.
Spread footings help distribute the load carried by the footings over a wider area.
As long as the concrete floor is at least a few inches thick it should be ok for temporary.
The spread part is a base that looks like an upside down t and transfers the weight across its area.
As part of this project i plan to cut a hole in the slab and pour a proper post footing using an 8 sonotube a simpson cb64 bracket and a bag of 5000psi sakrete.
The tiger brand jack post super s 4 the tiger brand jack post super s 4 ft.
Dave i would assume the basement is heated or the air in the basement never drops below 32 f.
I am nearly ready to replace my 4x4 basement support post.
Find my store.
It s not only the depth of the footing but also the size of the pad.
The spread footing should be no less than 6 inches thick.
Model j big moe.
Akron 19 in adjustable jack post.
May an inch or even less clearance all around.
Dig down 6 inches deeper than your basement floor surface.
I would plan on supporting more than a few of the joists using two or three adjustable columns.
It has a compression load range of 18 000 lbs.
For pricing and availability.
At its lowest setting and 14 000 lbs.
I will try to keep the hole small so that the sonotube is a fairly snug fit.
Jack post can adjust from 2 ft.